NF Board is a semi-non-combustible high-performance building insulation material that applies differentiated technology unique to Korea Polytechnics.
High insulation performance
- Initial thermal conductivity 0.020 W/mK or less
- Reduced thickness by up to 1/2 compared to existing insulation (according to KS L 9016-2010, authorized testing institute)
Fire safety
- Semi-non-combustible material (accredited testing institute)
- Conforms to the standard of non-combustible materials (Ministry of Land, Infrastructure and Transport notification No. 2015-744)
Economics
- Reduction of cooling and heating costs by perfect insulation effect, maximization of actual use area
Eco-friendly materials
- Environmental mark certification (Ministry of Environment Eco-Label), green building certification (HB Mark) addition point
- Use of C-Pentane foaming agent (HCFC-141b is an ozone-depleting substance that does not meet the certification standards)
- Minimize emissions of hazardous chemicals (VOCs)
High performance eco-friendly rigid polyurethane (PIR) foam insulation_HP Board
HP Board improves insulation and flame retardancy of existing PUR (Polyurethane), and
It is an eco-friendly high-performance building insulation material that applies the eco-friendly foam gas C-Pentane.
It is an eco-friendly high-performance building insulation material that applies the eco-friendly foam gas C-Pentane.
High insulation performance
- Initial thermal conductivity 0.023 W/mK or less
- Reduced thickness by up to 1/2 compared to existing insulation (according to KS L 9016-2010, authorized testing institute)
Economics
- Reduction of cooling and heating costs by perfect insulation effect, maximization of actual use area
Eco-friendly materials
- Environmental mark certification (Ministry of Environment Eco-Label), green building certification (HB Mark) addition point
- Use of C-Pentane foaming agent (HCFC-141b is an ozone-depleting substance that does not meet the certification standards)
- Minimize emissions of hazardous chemicals (VOCs)
Product classification and standards
Enforcement Rules of the Building Act for Fire Safety (Enforced in November 2019)
1. Current
Current | Applicable buildings and materials |
---|---|
Enforcement Decree of the Building Act (Article 61 (2)) | 3 stories or more or more than 9m |
Evacuation/fire prevention of buildings Rules for structures, etc. (Article 24, paragraph 5,6) |
1) Non-combustible material or semi-non-combustible on the outer wall
Obligation to use materials 2) Facing the exterior air of the pilotti structure Ceiling and wall |
2. Expanded application of flame retardant and semi-non-combustible materials
Expansion of the prohibition of combustible exterior materialsFlame retardant performance standards of building finishing materials and fire diffusion prevention structures
Classification | Semi-non-combustible material | |
---|---|---|
Korean Industrial Standards | KS F ISO 5660-1 (concalorimeter method) | KS F 2271 (Gas Hazard Test) |
Test method | 1. Total heat emission: 8 MJ/㎡ or less (10 minutes) 2. Maximum heat dissipation rate: 200kW/㎡ for more than 10 seconds ↓ 3. Harmful cracks of fire in the test body, No holes or melting |
Mean behavior of experimental rats Downtime 9 minutes or more |
NF Board |
Secured the technology that passed the standard of the large-scale fire test for exterior materials
division | Standard number | Standard name |
---|---|---|
제정(안) | KS_F_NEW_2018_2091 | Fire safety performance of building exterior finishing systems Part 1: Non-bearing wall exterior finishing system based on masonry |
KS_F_NEW_2018_2093 | Fire safety performance of building exterior finishing systems Part 2: Non-bearing wall external finishing system supported by steel structure | |
Evaluation standard | ||
As a result of the actual fire test according to BS 8414, from the time (ts) of maintaining 200° C. for 30 seconds at a point of 2.5 meters from the opening (Level 1)
Temperature (Ts) at 5 meters from the opening (Level 2) Do not exceed 600°C for 30 minutes for 15 minutes ▶ 15-minute fire diffusion delay performance verification |
||
▲ Manufacturing and testing of equipment for the selection of test methods for exterior materials (ISO 13785-2 vs BS 8414) (Fire Safety Research Group) |
High performance insulation_Initial thermal conductivity 0.020 W/mK or less
Comparison of insulation performance by product
Revision plan for energy-saving design standards for buildings ('18.9 enforcement)
Types and features of building insulation
Mineral Wool | phenol form | EPS (bead method 1,2) | XPS (extrusion method) | Hard urethane (general) | NF Board |
---|---|---|---|---|---|
Initial thermal conductivity (W/m•K) | |||||
0.037~0.040 | 0.020-0.030 | 0.031-0.039 | 0.027-0.034 | 0.020-0.023 | 0.020~0.023 |
KS L 9102 | KS M ISO 4898 | KS M 3808 | KS M 3809 | KS M 3809 | |
Key features | |||||
Poor insulation performance Excellent flame retardant performance due to absorbency Load burden Workability problem |
Excellent insulation performance Excellent flame retardant performance VOC emissions Weak water resistance Corrosive problem |
Poor insulation performance Poor flame retardant performance EPS Series Limits Excellent workability |
Insulation performance is usually Poor flame retardant performance Excellent water resistance Excellent workability |
Excellent insulation performance Excellent workability Excellent water resistance Semi-non-combustible performance implementation Very difficult |
Excellent thermal insulation performance ▲ Excellent workability ▲ Excellent water resistance ▲ Solving environmental issues ▲ Semi-non-flammable performance ▲ |